diff options
| author | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2017-10-09 09:02:35 +0200 |
|---|---|---|
| committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2017-10-09 09:02:35 +0200 |
| commit | 1236d6bb6e19fc72ffc6bbcdeb1bfefe450e54ee (patch) | |
| tree | 47da3feee8e263e8c9352c85cf518e624be3c211 /Documentation/networking/switchdev.txt | |
| parent | staging: irda: au1k_ir.c fix warning: Prefer [subsystem eg: netdev]_info([sub... (diff) | |
| parent | Linux 4.14-rc4 (diff) | |
| download | linux-1236d6bb6e19fc72ffc6bbcdeb1bfefe450e54ee.tar.gz linux-1236d6bb6e19fc72ffc6bbcdeb1bfefe450e54ee.zip | |
Merge 4.14-rc4 into staging-next
We want the staging/iio fixes in here as well to handle merge issues.
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation/networking/switchdev.txt')
| -rw-r--r-- | Documentation/networking/switchdev.txt | 68 |
1 files changed, 34 insertions, 34 deletions
diff --git a/Documentation/networking/switchdev.txt b/Documentation/networking/switchdev.txt index 5e40e1f68873..82236a17b5e6 100644 --- a/Documentation/networking/switchdev.txt +++ b/Documentation/networking/switchdev.txt @@ -13,42 +13,42 @@ an example setup using a data-center-class switch ASIC chip. Other setups with SR-IOV or soft switches, such as OVS, are possible. - User-space tools - - user space | - +-------------------------------------------------------------------+ - kernel | Netlink - | - +--------------+-------------------------------+ - | Network stack | - | (Linux) | - | | - +----------------------------------------------+ + User-space tools + + user space | + +-------------------------------------------------------------------+ + kernel | Netlink + | + +--------------+-------------------------------+ + | Network stack | + | (Linux) | + | | + +----------------------------------------------+ sw1p2 sw1p4 sw1p6 - sw1p1 + sw1p3 + sw1p5 + eth1 - + | + | + | + - | | | | | | | - +--+----+----+----+-+--+----+---+ +-----+-----+ - | Switch driver | | mgmt | - | (this document) | | driver | - | | | | - +--------------+----------------+ +-----------+ - | - kernel | HW bus (eg PCI) - +-------------------------------------------------------------------+ - hardware | - +--------------+---+------------+ - | Switch device (sw1) | - | +----+ +--------+ - | | v offloaded data path | mgmt port - | | | | - +--|----|----+----+----+----+---+ - | | | | | | - + + + + + + - p1 p2 p3 p4 p5 p6 - - front-panel ports + sw1p1 + sw1p3 + sw1p5 + eth1 + + | + | + | + + | | | | | | | + +--+----+----+----+----+----+---+ +-----+-----+ + | Switch driver | | mgmt | + | (this document) | | driver | + | | | | + +--------------+----------------+ +-----------+ + | + kernel | HW bus (eg PCI) + +-------------------------------------------------------------------+ + hardware | + +--------------+----------------+ + | Switch device (sw1) | + | +----+ +--------+ + | | v offloaded data path | mgmt port + | | | | + +--|----|----+----+----+----+---+ + | | | | | | + + + + + + + + p1 p2 p3 p4 p5 p6 + + front-panel ports Fig 1. |
